A sewage ejector pump lifts waste from toilets and drains that sit below the sewer line. This guide covers how the system works and what the 2025 California Plumbing Code requires.

Last updated: November 2026

A sewage ejector pump collects sewage from fixtures that sit lower than the sewer line and pumps it up into the building drain or sewer. Section 710.2 of the 2025 California Plumbing Code requires this kind of lifting system wherever drainage piping serves fixtures below the crown level of the main sewer.

Most San Diego homes sit on a crawlspace or a slab, so an ejector usually means a bathroom or ADU built lower than the street sewer. Maybe you just bought a house with a sealed basin in the floor.

How does a sewage ejector pump work?

A sewage ejector system works in a cycle. Waste from the low fixtures drains by gravity into a sealed, watertight basin. When the level in the basin reaches its starting point, the pump switches on automatically, pushes the sewage up through a discharge pipe into the building drain or sewer, then shuts off and waits for the next fill.

The pump sits inside that basin. As our sewage ejector pump installation page puts it, the pump “rests in a sewage pit, and is designed to handle the solids and liquids from sewage waste.” It takes what toilets, sinks and bathtubs send down, and it runs less often than a sump pump but with more force.

A check valve is a one-way valve on the discharge line, so what was just pumped can’t fall back into the basin. A shutoff valve after it lets a technician isolate the pump for service.

Our sewage pump installation page describes the setup as a sewage pit plus “a vent pipe to remove gases and odor.” The lid is sealed and usually bolted down. Nobody in the household should be opening it.

Where is an ejector required under the California Plumbing Code?

Under Section 710.2 of the 2025 California Plumbing Code, drainage piping that serves fixtures below the crown level of the main sewer has to discharge into an approved watertight sump or receiving tank. From there, the sewage must be lifted into the building drain or sewer by an approved ejector, pump or equally efficient mechanical device.

The crown is the top of the inside of the sewer pipe. Below that point, gravity can’t carry waste out, so it has to be pumped.

The California Plumbing Code is Part 5 of Title 24. According to the California Building Standards Commission, the 2025 edition took effect January 1, 2026. Local building departments, including those in San Diego County, enforce it and can add amendments. They have the final word on a specific job.

Section 710.1 adds a backwater valve for fixtures on a floor lower than the next upstream manhole cover. A backwater valve lets wastewater out but closes against sewage coming back in.

When the basin takes toilet or urinal waste, Section 710.3 requires a pump with a discharge capacity of at least 20 gallons per minute. Other minimums change with the building. Sections 710.3, 710.4 and 710.9 set different minimums for a single home and for other buildings.

Requirement Single dwelling unit Other buildings
Solids the pump must pass A 1-1/2 inch solid ball A 2 inch solid ball
Discharge pipe size At least 2 inches At least 3 inches
Valves on the discharge line Check or backwater valve, then a gate or ball valve Same
Failure alarm Audio and visual, readily accessible Audio and visual, readily accessible
Dual alternating pumps Only in “public use” occupancies Only in “public use” occupancies

What are the signs a sewage ejector is failing?

Our sewer ejector pump service page lists the warning signs. The pump doesn’t run even though the sewage level is rising. It runs constantly. It makes abnormally loud noises. Or waste backs up into the house. Any one of these means the system needs a technician.

The alarm is the other signal. Section 710.9 of the 2025 California Plumbing Code calls for an audio and visual alarm that signals pump failure or an overload condition. If yours is going off, assume one of those two until someone has looked.

A quiet pump can fool you. Silence feels like good news, but if the fixtures downstairs keep draining and the pump never kicks on, the basin is filling with nowhere to go.

We’ve covered alarms in “Your sump pump alarm went off. Now what?” and odor in “Sewer smell coming from your sump pit: causes and what to do.” With an ejector, stop sending water to the basin and call.

What should never go down drains that feed an ejector?

Our FAQ lists what doesn’t belong in the system: feminine pads, even ones labeled “flushable,” disposable and baby wipes, cotton swabs, diapers, paper towels and rags. Solvents, paint, grease and oil can damage the pump cord. An ejector is built for ordinary sewage, not for things that tangle or coat.

If something like rags or underwear does go down, our FAQ says to call 619-240-4013 right away. Don’t wait to see if the pump copes.

Guests and tenants often don’t know there’s a pump under the floor. A short note by the toilet helps.

What can a homeowner check, and what needs a licensed contractor?

A homeowner’s job is to notice trouble early and stop sending water to the basin. Anything that means opening the basin, touching sewage, pulling the pump or working on the controls belongs to a licensed pump contractor. Sewage contact is always the professional’s side of the line, and the basin is sealed for that reason. Our sump pump maintenance checklist draws the same line for sump pumps.

If the alarm is sounding, stop running water in the fixtures that drain to the basin. Every flush adds to a basin that may not be emptying. Check the breaker panel. If the pump’s circuit has tripped, you can reset it once. If it trips again, leave it off and call. Keep the lid closed and bolted.

Opening the lid, clearing a clog, replacing a check valve or a pump, or cleaning up sewage on the floor is contractor work. So is anything electrical past the breaker, and so is a new installation. Don’t reach into the basin to free a stuck pump or fish out a rag.

Frequently asked questions

Can a sump pump be used instead of a sewage ejector pump?

No. The sewage pump installation page on our site says it directly: “A sump pump cannot be used in place of a sewage pump.” A sewage pump is designed to handle the solids and liquids from sewage waste, in a basin with a sealed lid and a vent. A sump pump moves groundwater.

Does a house need two sewage ejector pumps?

Usually not. Section 710.9 of the 2025 California Plumbing Code requires dual pumps, arranged to alternate, only where the building is a “public use” occupancy. Outside that, the section doesn’t call for a second pump, though a second one can still be added for backup. Your building department decides how a specific property is classified.

Why does a sewage ejector basin have a vent pipe?

The vent keeps the basin at normal air pressure and carries gases and odor out of the house. Section 710.10 of the 2025 California Plumbing Code requires the vent to be at least 1-1/2 inches in diameter and to run through the roof on its own or, where permitted, combine with other vents. Don’t cap or cover it.

Is a grinder pump the same as a sewage ejector?

Not exactly. Both lift sewage to a higher drain or sewer, and both are allowed under the 2025 California Plumbing Code. Section 710.12 permits grinder pumps with discharge piping of at least 1-1/4 inches, while Section 710.3 calls for at least 2 inches on a standard ejector in a single home. A technician can tell you which one you have.

How Fox Pump Systems can help

Fox Pump Systems installs and services sewage ejector systems throughout San Diego County. Steve Fox has worked on sewage and sump pumps since 1986, and our technicians are certified in Confined Space Entry. Work inside a sewage basin belongs to people trained for it. If your ejector is acting up, we find the cause and repair or replace what’s needed. To catch problems early, ask about a planned maintenance program. Fox Pump Systems holds CSLB Lic #928391. If sewage is backing up or the alarm is sounding, call 619-240-4013. Emergency pump service is available 24/7. For anything that can wait, send a service request.

Previous Post

Sump Pump Maintenance Checklist: What a Service Visit Should Cover